Agriculture
Agriculture
  • About Us
  • News & Updates
    • Release Notes
    • Press Releases
  • Blog
  • Trimble.com
    • English
    • English(UK)
    • Français
    • Deutsch
    • Español
    • Italiano
    • Русский
    • Українська
    • Español, Argentina
    • Español, Mexico
    • Türkisch
    • Português
  • Facebook
  • LinkedIn
  • Twitter
  • YouTube
  • Instagram
Agriculture
  • Products
  • Solutions
    • Land Preparation
    • Guidance & Steering
    • Correction Services
    • Planting & Seeding
    • Flow & Application Control
    • Water Management
    • Data Management
    • Harvest
  • Trimble Partners
    • OEM Solutions
    • Vantage Distribution Partners
    • Become a Reseller
    • Trimble Select
  • Support
  • Virtual Farm
  • Trimble Ag’s Response to COVID-19
  • How to Buy
  • Login
  1. How-to Central
  2. Search Results
  3. Hardware Requirements

Hardware Requirements

To run FarmStream Fleet, a vehicle must have an FmX® integrated display, a GFX-750™ display, a GFX-350™ display or a TMX-2050™ display installed. FarmStream can use one of many wireless connectivity options including the DCM-300 modem as well as the GX450 modem, SNM941 Connected Site Gateway, Wi-Fi, and WAN gateways.

Customers may use the Precision-IQ or FmX+ app on the TMX-2050 display or the Precision-IQ app on the GFX-750 or GFX-350 display. The Precision-IQ app prior to version 5.50 firmware for TMX or 1.50 firmware for GFX-750 has limited FarmStream functionality only.

Customers who have the DCM-300 modem and the FmX or TMX-2050 display set up on a vehicle can choose whether they want to use the traditional or FarmStream version of Fleet for that vehicle. Customers who own these devices can use FarmStream and traditional Fleet on different vehicles in their fleet and see the data from both versions of Fleet in one organization.

Customers using traditional Fleet can still use the DCM-300 modem to track their fleet’s utilization, but traditional Fleet does not link with the display and provides utilization data solely based on vehicle movement and the optional use of an implement switch.

The following table summarizes the hardware options for FarmStream Fleet:

 

Hardware used  Description and requirements
DCM-300 modem, FmX display If the DCM-300 modem is used with FarmStream, it is used as a modem only and not as a vehicle CAN interface. The FmX display requires version 10.01 or higher firmware.
DCM-300 modem,
TMX-2050  display
 If the DCM-300 modem is used with FarmStream, it is used as a modem only and not as a CAN interface. The TMX-2050 display requires version 4.3.1 or higher firmware for the FmX+ app and version 5.50 or higher for the Precision-IQ app.
GX450 or SNM941 modem, FmX display If the GX450 or SNM941 modem is used with FarmStream, it is used as a modem only and not as a CAN interface. The FmX display requires version 10.01 or higher firmware.
GX450 or SNM941 modem, TMX-2050 display If the GX450 or SNM941 modem is used with FarmStream Fleet, it is used as a modem only and not as a CAN interface. The TMX-2050 display requires version 4.3.1 firmware for the FmX+ app and version 5.50 or higher for the PIQ app.
Third party WAN gateway device, FmX display FarmStream Fleet may be used with a third-party WAN gateway device for connectivity, such as a cellular device. It must be connected to the display. The FmX display requires version 10.01 or higher firmware.
Third party WAN gateway device,
TMX-2050 display
FarmStream Fleet may be used with a third party WAN gateway device for connectivity, such as a Wi-Fi or cellular device. Smartphone tethering may be used as a source of connectivity for the TMX-2050 display.  The TMX-2050 display requires version 4.3.1 or higher firmware for the FmX+ app and version 5.50 or higher for the PIQ app.
GX450 or SNM941 modem,
GFX-750 or GFX-350 display
If the GX450 or SNM941 modem is used with FarmStream, it is used as a modem only and not as a CAN interface. The GFX-750 display requires version 1.50 firmware or higher for full FarmStream functionality. Any version of GFX-350 firmware is compatible with Farmstream.
Third-party WAN gateway device,
GFX-750 or GFX-350 display
FarmStream Fleet may be used with a third-party WAN gateway device for connectivity, such as a Wi-Fi or cellular device. Smartphone tethering may be used as a source of connectivity for the GFX display.  The GFX-750 display requires version 1.50 firmware or higher for full FarmStream functionality. Any version of GFX-350 firmware is compatible with FarmStream.


The following table summarizes the hardware options for traditional Fleet:

Hardware used  Description and requirements
 DCM-300 modem, no display This version of the traditional Fleet uses the DCM-300 modem to obtain utilization data based on vehicle movement and  the optional use of an implement switch.
DCM-300 modem,
TMX-2050 display
This version of the traditional Fleet uses the DCM-300 modem to obtain utilization data based on vehicle movement and optional use of an implement switch.
It does not link the DCM-300 modem with the TMX-2050 display.
DCM-300 modem,
FmX display
This version of the traditional Fleet uses the DCM-300 modem to obtain utilization data based on vehicle movement and optional use of an implement switch.
It does not link the DCM-300 modem with the FmX display.

 

Search How-To Central:

How-To Central Categories

Trimble Agriculture
  • Products
  • Tractor Guidance
  • ISOBUS Compatible Input Control
  • Record-Keeping
  • Crop Planning
  • Yield Monitoring
  • Farm Finance Management
  • Advanced Positioning
  • Land Forming
  • Solutions
  • Land Preparation
  • Guidance & Steering
  • Correction Services
  • Planting & Seeding
  • Flow and Application Control
  • Water Management
  • Data Management
  • Harvest
  • Trimble Select
  • Trimble AG
  • Support
  • How to Buy
  • Privacy Policy
  • Do Not Sell My Personal Information
  • Facebook
  • LinkedIn
  • Twitter
  • YouTube
  • Instagram
Trimble Inc. © 2022, All Rights Reserved| Privacy Policy
  • English
  • English